Explore our in-depth guide to designing clear, intuitive and reliable user interfaces with light indicators.
During normal operation, users often glance at a machine's control panel to find a button, check a stage of the process or see whether they can proceed. The designer must make this information easy to understand while fitting the display, controls and indicator lights into a layout that is already defined and often cramped.
An RGB indicator can help save space by using different colours at the same light point, provided the conditions being signalled occur one at a time and each colour has a clear meaning.
Add several functions to one light point.
- When Can an RGB Indicator Replace Several Indicator Lights?
- Compact Panels: Consider the Space Taken Up by the Whole System
- How to Assign Colours to Machine States
- The Advantage of RGB: Recognising a State at a Glance
- Electronic Integration: What to Check Before Selecting a Component
- Examples of RGB Indicators in Different Applications
- Designing an RGB Indicator: Project Checklist
- Frequently Asked Questions
- Additional Tips
- Glossary
- Review Your Design Before Prototyping
An RGB indicator contains red, green and blue light sources. The electronic control board can activate each channel separately or combine them to produce hundreds of different colours. This allows the manufacturer to use the same light point to show conditions that occur in sequence, such as standby, operation and a request for intervention.
In an HVAC unit, for example, one colour could indicate the selected operating mode and another a standby condition. If a fault appears while the machine is running, the system must determine which indication takes priority and how to make the alert visible.
The same principle applies to outdoor and gardening equipment. An irrigation controller could use different colours to distinguish between standby, an active programme and a request to check the system. On a robotic lawn mower, an RGB indicator could show the operating mode, charging or the need for intervention.
One light point can communicate several alternating states; simultaneous alerts need a clear hierarchy.
Reducing the number of holes can free up space for displays, controls and labels. However, the mechanical benefit does not automatically mean less wiring or lower costs. The designer must also consider the board's outputs, connections, firmware management and production checks.
The table below summarises common design problems and possible ways to address them.
An RGB indicator can also support the management of OEM variants. If several machine versions share the same front panel and control board, the design can use a common component and assign its functions according to each configuration. This approach requires consistency between the components, wiring, firmware and assembly instructions.
To define colour coding, the designer can create a map with four details: the state to be shown, the condition that activates it, the assigned colour and the condition that turns it off. This makes clear when the indicator changes colour and which event the operator needs to recognise.
Applications differ from one sector to another. On a household appliance, the map could distinguish the stages of a cycle. On HoReCa equipment, it could show that the machine is ready or needs attention. A vending machine could use colour to indicate that a service is available or that it needs replenishing. An automation line could distinguish between standby and operation, while a home automation system could use different colours for selected modes.
HVAC systems, medical equipment and mobility applications may also need dedicated signals. These could indicate an active mode, a request for assistance or the status of lift doors. These are design examples rather than universal codes: manufacturers must check the conventions and requirements that apply to their equipment. The firmware must also define the indicator's behaviour at start-up, during transitions and when an alert ends.
Map the full signal cycle:
activation, duration and return to the normal state.
An RGB indicator can communicate different conditions through the same light point. The operator can recognise a change of state without looking for another indicator elsewhere on the panel, while the designer has more freedom to position the display, controls and other indicators.
The colour coding must work with the rest of the interface. A colour selected without considering the background, lens and other illuminated elements may blend into the panel. The designer should therefore test the component once it is mounted, checking contrast and recognisability from the position where users will view the machine.
The Federal Aviation Administration offers a useful reference in its report on visual status coding. The report addresses the needs of specialists who monitor and control more than 30,000 technical services and items of equipment. It highlights the value of clear, consistent methods for recognising operating conditions quickly. The report does not measure the performance of a specific RGB indicator, but it provides an authoritative reference on visual coding in technical interfaces.
The machine's control board manages the RGB channels. Before choosing a component, the designer must compare the required voltage and output characteristics with the component's technical documentation. The person developing the firmware must also define what the machine shows at start-up, during operation and when it detects a fault.
The control logic must specify how to handle states with different priorities. If an alert takes precedence over a normal operating mode, the system must make that alert clear and keep it recognisable in the conditions expected for the application. The prototype lets the designer check whether the transition between colours is clear and whether the indication remains visible at each stage.
For projects that require several colours to indicate machine status, the SLIM TB/RGB signal unit combines an RGB LED with a PVC cable connection. It is available in nominal voltages from 6 to 400 V, making it suitable for projects with different colour-signalling and electrical integration requirements.
To request a sample, send SLIM the panel drawing, front-panel thickness, hole diameter and available voltage. Include the states you want to signal and the conditions in which users will view the indicator. With this information, SLIM can assess whether the TB/RGB is compatible with the planned mounting and circuit, then prepare a sample for testing on the prototype.
Do you have specific design requirements?
The designer chooses how to use an RGB indicator according to the information the machine needs to communicate and the people who will use it. On HoReCa equipment, for example, a colour could show that a coffee machine or professional dishwasher is ready to use. A drinks dispenser could use the indicator to show whether the service is available or the machine needs replenishing, bearing in mind that users may not be familiar with the equipment.
On household appliances, colour can accompany the stages of a washing cycle or show the status of an oven. The same approach applies to heating units, commercial refrigerators and air-treatment equipment: an indicator can show the active mode or flag a maintenance request. In each case, the message needs to make sense during normal use.
On automation panels and machine tools, operators may need to distinguish between standby, operation and a request for intervention. In lighting and home automation systems, a light point could show a selected mode or the status of a control. Medical equipment and mobility systems, from vehicles to lifts, require a specific assessment to determine which information can be conveyed through colour and which should have a dedicated indicator.
IEC 60204-1 covers the electrical equipment of machinery, including aspects relating to control devices and control circuits. Before defining the panel's colour coding, the designer must identify the standards that apply to the equipment and its intended sector.
The same component can serve different applications;
its signal should reflect how each machine is used.
Before selecting a component or requesting a sample, check the following:
A bi-colour indicator offers two defined colours. An RGB indicator uses red, green and blue channels to produce more combinations. The choice depends on the states to be shown, the machine's control logic and the component's electrical characteristics.
An RGB LED can produce white light through additive colour mixing: when the red, green and blue chips are switched on at the same time with balanced intensities, the eye perceives white. Varying the balance between the three channels, usually through PWM, can shift the white towards warmer or cooler tones. An RGBW version is also available for applications that need a more effective white light.
The light output can vary according to the component and production tolerances. The manufacturer can define a reference sample and approval criteria to check consistency between batches.
Prepare the panel drawing, material thickness, hole diameter, available voltage and list of functions to be signalled. Add a description of the expected viewing conditions.
Yes, if the variants share compatible mechanical and electrical requirements and the firmware can manage their different functions. The manufacturer should also check assembly requirements and production documentation.
Consider the diameter, lens finish, position and light intensity alongside the display, controls and surrounding materials. Testing the indicator on the complete panel helps assess its appearance and readability.
Define what the indicator shows during start-up and self-diagnostics, before the machine reaches its operating state.
Add a photograph of the approved panel to the assembly documentation to help check product variants.
Include a check in the maintenance plan to confirm that the displayed colours still correspond to the machine's functions.
Further reading
Designing control panels with light indicators
Criteria for integrating light signals into a panel.
Choosing LED components based on cost and performance
Factors to compare when selecting components.
Reducing time-to-market with light indicators
Guidance on integrating components during OEM development phases.
Customized lighting solutions for OEM projects
An overview of customization options.
PWM
Pulse-width modulation: an electronic technique that controls average power through rapid on-and-off pulses.
RGBW
An LED configuration that adds a dedicated white channel to the red, green and blue channels.
Binning
The process of sorting LEDs into groups with similar light output characteristics.
EMC
Electromagnetic compatibility: an item of equipment's ability to operate without causing or being affected by unacceptable electromagnetic interference.
Panel requirements depend on dimensions, materials, available voltage and the functions to be signalled. With the drawing and this information, the SLIM team can assess whether an RGB indicator is compatible and help guide component selection. This discussion is useful both during design and when a prototype reveals a space or integration issue.
Do you already have a panel layout